<LOGO>
FM Transmitter Measurement Report
Created: 2024-02-23 03-50-47
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
101.90 MHz 5/5, 42 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
6 kHz 8 kHz 18664 0,0911
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-1,7 dBr -1,12 dBr -0,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 3:50, 23.02.2024
RT
"Pro a proti - Humor, ktery nikomu neublizuje ? je to ideal, o..."
AF EON
91.3, 91.5, 92.6, 92.8, 93.3, 93.5, 93.9, 94.1, 95.4, 97.8, 100.8, 101.5, 101.9, 103.6, 107.2 MHz -
FM Scope Max at: 8 kHz MIN: 6 kHz % above 77 kHz: 0,0911 Acquired: 2024/02/23 3:50:44 Total samples: 18664 Equivalent time: 0:15:33 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: -0,6 dBr MIN: -1,7 dBr AVE: -1,12 dBr % above 0,2 dBr: 0,0 Last value: -1,3 dBr (2024/02/23 3:50:44) 03:36 03:38 03:40 03:42 03:44 03:46 03:48 03:50 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality